The NCI scale install program will provide functionality within UPS OnLine WorldShip 6.0. for NCI models 3835, 3825, 78xx series, 7815, 7620 and LPS 150/400 To run the install program place the install disk or CD in the appropriate drive. If using Windows Explorer locate that drive and double click on Scainstl.exe. The message "This program will install the NCI Scale Definition file for UPS WorldShip" is displayed. Click "OK" and the program will install in the directory required by the UPS WorldShip application. Click "OK" again to complete the install. You will need to access the WorldShip Settings menu to locate and select the model scale you are connecting to. The standard out of the box default settings are used for each model in this application. This default configuration for protocol (76/78xx models only), baud rate, data bit and parity settings on the scale are set as follows. 3835 - 4800,7,e 3825 - 9600,7,e 78xx Family - NCI,9600,7,e 7815 .1 RevB - NCI,9600,7,e (display prompt "02-02") 7815 .1 New - 9600,7,e (display prompt "02-03" or higher) 7620 - NCI,9600,7,e (works only in dec lb mode, does not support lb-oz) LPS 150/400 - 9600,7,e The 7815 "RevB" uses 3 status bytes while "New" uses 2 status bytes. Use these selections only if resolution is by 0.1lb for 0.05lb use 78xx Family selection